Is It Time to Change the Liquid Line Drier? - Moe - Heating & Cooling (2024)

11 days agoby MoeHeatingCoolingin Uncategorized4

“Every time a system is opened for service, it’s at all times a good suggestion to switch the liquid line drier.”

– Justin Bailey

Technical coach

Heatcraft Refrigeration Merchandise

A liquid line drier is essential to battling a formidable opponent: moisture. That makes it one of the vital necessary — but least costly — elements of a refrigeration system.

Moisture is a significant reason for compressor failure. It could possibly work together with halocarbon refrigerants and switch into hydrochloric and hydrofluoric acid, which, over time, will destroy elements, in addition to soften and eat away the insulation from the compressor motor windings.

The liquid line drier’s most important operate is eradicating moisture. It could possibly additionally catch particulates similar to copper chips or small items of particles, stopping them from ending up the place they will trigger harm. Every time a system is opened for service, it’s at all times a good suggestion to switch the liquid line drier.

In an working system, if there’s a moisture indicator and it exhibits warning or moisture, the drier must be changed. Additionally, a stress or temperature drop throughout the drier signifies it’s turning into clogged. Examine the temperature of the road coming into and leaving the drier. If there’s greater than 1°F distinction or greater than a 2 psig drop, change the drier.

In a brand new set up, the drier will usually be within the liquid line, simply outdoors of the receiver. Set up a sight glass/moisture indicator instantly after the drier to offer the vacuum pump ample time to take away air and moisture.

When changing a failed compressor, find the drier as near the enlargement valve as doable to make sure any contaminants or particulates within the liquid line are trapped within the drier. Including a suction filter as near the compressor as doable will assist catch particles and shield the brand new compressor.

Utilizing a bigger drier with extra desiccant, like a 303S as an alternative of a 163S, or a replaceable core drier that’s changed after a certain quantity of run time, may also help clear up the system and lengthen the lifetime of the substitute compressor. Vacuuming correctly throughout set up and repair can also be necessary to moisture removing.

Selecting the Right Drier

Understanding the totally different properties of drier media will aid you select the right drier for the system. The 2 most important kinds of desiccants utilized in driers are:

  1. Activated alumina, which may seize bigger quantities of moisture to assist lengthen the drier’s life; and
  2. Molecular sieve-type driers, which not solely seize moisture, but in addition assist with acid in a contaminated system.

Liquid line driers come in several sizes for each the road dimension and quantity of desiccant within the drier. A 163S drier, for instance, comprises 16 cubic inches of desiccant and suits a 3/8-inch line. A 083S drier suits the identical dimension line however solely has half as a lot desiccant, whereas a 164 SAE drier is a flare type for a half-inch line. The primary numbers are desiccant quantity, and the final digit is line dimension in 1/8-inch increments. The letter S denotes sweat or braze, and SAE is the flare kind.

Commonplace driers are directional and have a stream arrow stamped on them. Warmth pump programs require a bi-flow drier. A chart on the drier field lists the refrigerants it really works with and the tonnage of the system it may deal with. This sometimes applies to a system that’s in good working order. A system contaminated by a burned out compressor — or one with moisture — may have a a lot bigger drier. A drier might have gauge ports on one or each side to learn stress drop.

Suction filters can be utilized on the suction line, and utilizing a suction filter along side a liquid line drier can provide most cleanup of a contaminated system. Suction filters generally is a desiccant kind or made with only a filtration media. Which sort you choose is decided by system contamination. Replaceable core kinds can be found for each liquid driers and suction filters and are a superb possibility for contaminated and bigger programs that may require a number of drier adjustments.

Putting in the Drier

After system restore or compressor substitute, the drier ought to be the very last thing put in. Uncap it as briefly as doable earlier than set up.

As soon as the system has been put again into service — and after a number of days or even weeks of regular operation – it is best to change the liquid line drier and take away the suction filter. Testing the refrigerant and oil for acid after changing a failed compressor will assist decide if further drier adjustments are warranted.

Changing driers is way cheaper than having further failures and misplaced product. Conserving a refrigeration system clear and dry by altering the liquid line drier — along with routine upkeep — could be the least costly insurance coverage towards failure.

Whether you require installation, repair, or maintenance, our technicians will assist you with top-quality service at any time of the day or night. Take comfort in knowing your indoor air quality is the best it can be with services Ontario's solution for heating, air conditioning, and ventilation that’s cooler than the rest.
Contact us to schedule a visit. Our qualified team of technicians, are always ready to help you and guide you for heating and cooling issues. Weather you want to replace an old furnace or install a brand new air conditioner, we are here to help you. Our main office is at Kitchener but we can service most of Ontario's cities

Supply hyperlink

air conditioning Air conditionor Air quality compressor troubleshooting Cooling repair Dehumidifiers Drier Filters Frostlines Furnace installation Furnace repair Heat pumps Heating Systems Hot water tanks Humidifiers Line Liquid liquid refrigerant Moisture Control Replace Tankless water heater Time troubleshooting and HVACR Ventilators Water heater

Add Comment

Related Posts

Funding Agency Acquires Nashville HVAC Distributor

HVAC Advertising: The Final Checklist of Do’s and Do Not’s
Is It Time to Change the Liquid Line Drier? - Moe - Heating & Cooling (2024)

FAQs

When should the liquid line drier be replaced? ›

Whenever a system is opened for service, it is always a good idea to replace the liquid line drier. In an operating system, if there is a moisture indicator and it shows caution or moisture, the drier needs to be replaced. Also, a pressure or temperature drop across the drier indicates it is becoming clogged.

What happens if you don't replace the filter drier? ›

Unwanted moisture will compromise the correct lubrication of a system and run the risk of internal corrosion. Any unfiltered particles allowed to freely circulate the loop will eventually clog up the system's components (condenser, expansion valve and evaporator) and/or cause the compressor to seize.

How often should you replace a receiver drier? ›

It is a cardinal principle to replace the receiver drier or dessicant bag whenever a system is serviced or open to the atmosphere - as per the Australian Code of Practice. All filter driers should be replaced every 2 years or by manufacturer's recommendation.

Do I need to change the filter drier? ›

Each time that a reoperation of the cooling system is carried out replacing the filter drier with a new one is required, because as the filter becomes saturated with water, the desiccant can no longer absorb moisture – the filter drier can't be reused.

What happens if you put a liquid line drier in backwards? ›

If installed backwards, the filter drier will become useless.

How can a technician determine when a filter drier is stopped up and needs changing? ›

Final answer: The correct answer is option c which is 'By monitoring the pressure drop across the drier'. To determine when a filter drier is clogged and needs changing, monitor the pressure drop across the drier to ensure system efficiency and prevent damage.

How long does a filter drier last? ›

As a general rule of thumb, it is recommended to replace your filter drier every 2-5 years, depending on the specific type of filter drier and the amount of use your air conditioning system gets. However, it is also important to regularly inspect your filter drier for signs of wear and tear.

How much does it cost to replace a receiver drier? ›

The average cost for an Air Conditioning Receiver Drier Assembly Replacement is between $328 and $409. Labor costs are estimated between $168 and $212 while parts are priced between $159 and $197.

When replacing an AC compressor, what else should be replaced? ›

Replacing the air conditioning system means putting in a condenser and a new indoor evaporator coil, while leaving the rest of the HVAC system in place. This is the most common choice when a compressor that's no longer under warranty dies.

What happens if you don't replace the receiver drier? ›

If the AC system is worked on and open to the atmosphere, the desiccant can quickly become saturated from the humidity in the air. When this occurs, the dryer is no longer effective and the excessive moisture in the system can cause corrosion and degrade the performance of the compressor's lubricating oil.

What happens if you don't install a filter drier? ›

Once there's moisture in the system, acid can form, seriously damaging the expensive, more glamorous components. There-fore, it's important to choose the correct filter-drier for the application, and then size it and install it correctly, if you want to head off problems down the road.

Can you run an AC without a filter drier? ›

Your AC system needs a filter drier to prevent refrigerant from freezing inside of it. Under normal circ*mstances, refrigerant shouldn't freeze.

Do you have to replace receiver drier? ›

The receiver drier rarely needs to be replaced alone, but when you replace other components of your vehicle's air-conditioning system, it will need replacing to ensure the warranty. It's important to ensure that moisture entering the system is quickly absorbed.

When should refrigerant lines be replaced? ›

Refrigerant lines typically last 20-25 years. Any damage or contamination can shorten the lifespan of your lines, but typically that's how long they should last. To ensure that you get the full life expectancy out of your lines, make sure you get a high-quality install from a trusted technician.

References

Top Articles
Latest Posts
Article information

Author: Neely Ledner

Last Updated:

Views: 6440

Rating: 4.1 / 5 (62 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Neely Ledner

Birthday: 1998-06-09

Address: 443 Barrows Terrace, New Jodyberg, CO 57462-5329

Phone: +2433516856029

Job: Central Legal Facilitator

Hobby: Backpacking, Jogging, Magic, Driving, Macrame, Embroidery, Foraging

Introduction: My name is Neely Ledner, I am a bright, determined, beautiful, adventurous, adventurous, spotless, calm person who loves writing and wants to share my knowledge and understanding with you.